How to Operate the Ozone Generator Correctly?

Jan. 04, 2021

As a Water Ozone Generator Manufacturer, share it with you.

Abstract: The correct operation of the power switch of the ozone generator may be indifferent to some users. Anyway, one click to open it, in fact, this is a mistake. As a device with a precision electric board, it is like a computer. Switch rules to minimize

Correctly operating the power switch of the ozone generator may feel that it doesn’t matter to some users. Anyway, it’s a typo. As a device with a precision electric board is like a computer, some switching rules need to be formulated. To minimize the damage of the power supply to the equipment. In the past, most computer monitors used cathode ray tubes, commonly known as "big butt". If you turn on the host first and then turn on the display, the current and voltage will suddenly increase and burn the host. The current display uses led and cld. Which component is turned on first will damage the host. It's relatively small, but humans have become accustomed to turning on the display before turning on the host.

Large Water Ozone Generator

Large Water Ozone Generator

Similarly, the ozone generator is expensive, the replacement of the original is complicated, and the after-sales maintenance is cumbersome, so try to do the manufacturer's guidance and suggestions.

Connect before standby

1. Connect the oxygen pressure reducer to the medical oxygen cylinder.

2. Connect the oxygen pressure reducer to the oxygen connecting pipe.

3. Turn the valve switch of the medical oxygen cylinder counterclockwise for half a turn to one turn. The high pressure gauge of the oxygen pressure reducer shows that it is greater than 0.5MPa. Turn the adjustment knob of the oxygen pressure reducer clockwise to empty the air in the connecting pipeline under low pressure. After venting the air, connect the oxygen connecting pipe to the oxygen input connector of the instrument and fix it with an external fixing cap.

4. After the connection is completed, turn the oxygen pressure reducer adjustment knob clockwise to adjust the oxygen output pressure to 0.4MPa. The low pressure meter of the oxygen pressure reducer shows 0.4MPa, which is not less than 0.2MPa and not more than 0.5MPa.

5. Connect the main power cord to the main power interface of the instrument, and then connect the main power cord to the power supply (or UPS power supply). Do not overload the power supply.

6. Turn on the main power switch and the instrument will perform system self-check. After the self-check is completed, the instrument enters a standard standby state.

Our company also has Large Water Ozone Generator on sale, welcome to contact us.